Wire Gauge (AWG) Size Chart
Convert American Wire Gauge to millimeters and inches, with copper resistance.
| AWG | Diameter (mm / in) | Area (mm²) | Copper Ω/km |
|---|---|---|---|
| 0000 (4/0) | 11.684 / 0.4600 | 107 | 0.1608 |
| 000 (3/0) | 10.405 / 0.4096 | 85.0 | 0.2028 |
| 00 (2/0) | 9.266 / 0.3648 | 67.4 | 0.2557 |
| 0 (1/0) | 8.251 / 0.3249 | 53.5 | 0.3224 |
| 1 | 7.348 / 0.2893 | 42.4 | 0.4066 |
| 2 | 6.544 / 0.2576 | 33.6 | 0.5127 |
| 3 | 5.827 / 0.2294 | 26.7 | 0.6465 |
| 4 | 5.189 / 0.2043 | 21.2 | 0.8152 |
| 5 | 4.621 / 0.1819 | 16.8 | 1.028 |
| 6 | 4.115 / 0.1620 | 13.3 | 1.296 |
| 7 | 3.665 / 0.1443 | 10.5 | 1.634 |
| 8 | 3.264 / 0.1285 | 8.37 | 2.061 |
| 9 | 2.906 / 0.1144 | 6.63 | 2.599 |
| 10 | 2.588 / 0.1019 | 5.26 | 3.277 |
| 11 | 2.305 / 0.0907 | 4.17 | 4.132 |
| 12 | 2.053 / 0.0808 | 3.31 | 5.211 |
| 13 | 1.828 / 0.0720 | 2.62 | 6.571 |
| 14 | 1.628 / 0.0641 | 2.08 | 8.286 |
| 15 | 1.450 / 0.0571 | 1.65 | 10.45 |
| 16 | 1.291 / 0.0508 | 1.31 | 13.17 |
| 17 | 1.150 / 0.0453 | 1.04 | 16.61 |
| 18 | 1.024 / 0.0403 | 0.823 | 20.95 |
| 19 | 0.912 / 0.0359 | 0.653 | 26.42 |
| 20 | 0.812 / 0.0320 | 0.518 | 33.31 |
| 21 | 0.723 / 0.0285 | 0.410 | 42.00 |
| 22 | 0.644 / 0.0253 | 0.326 | 52.96 |
| 23 | 0.573 / 0.0226 | 0.258 | 66.79 |
| 24 | 0.511 / 0.0201 | 0.205 | 84.22 |
| 25 | 0.455 / 0.0179 | 0.162 | 106.2 |
| 26 | 0.405 / 0.0159 | 0.129 | 133.9 |
| 27 | 0.361 / 0.0142 | 0.102 | 168.9 |
| 28 | 0.321 / 0.0126 | 0.0810 | 212.9 |
| 29 | 0.286 / 0.0113 | 0.0642 | 268.5 |
| 30 | 0.255 / 0.0100 | 0.0509 | 338.6 |
About this tool
Select an AWG size to see its diameter and the DC resistance of copper wire in that size. Confusingly, a larger AWG number means a thinner wire — this is a legacy of how the gauge numbering was originally defined by the number of drawing passes needed to produce it.
Nails use a different gauge scale; see the nail size chart.
Using the resistance figure. Resistance lets you estimate voltage drop. A circuit with 10 ft of 14 AWG each way has 20 ft of conductor: 20 ÷ 1000 × 2.525 Ω = about 0.05 Ω. At 10 A that loses about 0.5 V.
Source for diameters, areas and resistance: American wire gauge (Wikipedia), checked 2026-11-28.
Frequently asked questions
- Why is a higher AWG number a thinner wire?
- AWG numbering originated from wire manufacturing: thinner wire required more passes through progressively smaller drawing dies, so a higher "pass count" (and therefore higher gauge number) meant a thinner result. The numbering stuck even as manufacturing methods changed.
- How many amps can each gauge carry?
- There isn't one safe number per gauge, so this chart doesn't list one. The allowed current depends on the insulation's temperature rating, how many wires are bundled together, the surrounding temperature, the run length and the rules for that kind of installation. For household wiring, follow your local electrical code or use a qualified electrician. For equipment, vehicle or electronics wiring, use the wire maker's datasheet or the standard that applies to that work.
- Does wire material (copper vs aluminum) change these figures?
- Diameter and area are the same for any metal, but the resistance figures here are for copper. Aluminum has higher resistance for the same gauge, so it loses more voltage and is typically rated for less current.